Temank Solar Inverter Charger 3KW 120V AC MPPT 60A Solar Charge Controller PV 100V lifepo4 Battery And Lead Acid Battery
Pow series is a new hybrid solar charge inverter, which integrates solar energy storage & means charging energy storage and AC sine wave output. Thanks to DSP control and advanced control algorithm, it has high response speed, high reliability and high industrial standard. Four charging modes are optional.Based on full-digital intelligent design, the DC-AC inverter module employs advanced SPWM technology and outputs pure sine wave to convert DC into AC. It is ideal for AC loads such as household appliances, power tools, industrial equipment, and electronic audio and video equipment.
Feature:
- Brand: PowMr
- Product Model: POW-LVM3K-24V-H
- Full digital voltage and current double closed loop control, advanced SPWM technology, output of pure sine wave
- Two output modes: mains bypass and inverter output; uninterrupted power supply
- Available in 4 charging modes: Only Solar, Utility Priority, PV Priority, Utility & Solar hybrid charging
- Advanced MPPT technology with an efficiency of 99.9%
- Designed with a LCD screen and 3 LED indicators for dynamic display of system data and operating status
- Manual ON/OFF switch controlling AC output
- Power saving mode available to reduce empty load loss
- Intelligent variable speed fan to efficiently dissipate heat and extend system life
- Lithium battery activation by PV solar or mains, allowing access of lead-acid battery and lithium battery
Complete protections, including short circuit protection, over voltage and under voltage protection, overload protection, reverse protection, etc
Model |
POW-LVM3K-24V-H |
Utility/Grid |
|
Rated input Voltage |
110/120Vac |
Input voltage range |
120~450Vdc |
Frequency |
50Hz/ 60Hz (auto detect) |
Frequency range |
47±0.3Hz ~ 55±0.3Hz (50Hz); |
Overload / Short circuit Protection |
Breaker |
Efficiency |
>95% |
Conversion time (Bypass and reverse) |
10ms |
Reverse Flow Protection |
Yes |
Max Bypass Current load |
40A |
Inverter |
|
Waveform |
Pure Sine Wave |
Rated Output (VA) |
3000 |
Rated Output (W) |
3000 |
Power factor |
1 |
Output AC Voltage |
120Vac |
Unstable Input Error |
±5% |
Output Frequency (Hz) |
50Hz ±0.3Hz 60Hz ± 0.3Hz |
Efficiency |
>92% |
Overload protection |
For U model: |
(102% < load <110%) ±10%: report error and turn off |
|
Load >125% ±10%: report error and turn off the output after 5 seconds; |
|
Peak power |
4500VA |
Motor Capability |
2HP |
Output Short-circuit Protection |
Breaker |
Bypass Breaker Specifications |
40A |
Rated Battery Voltage |
24V (Minimum starting voltage 22V) |
Battery voltage range |
20.0Vdc~33Vdc ± 0.6Vdc |
Power Saving Mode Self-Consumption |
≤50W |
No Load Self Consumption |
48W |
Model |
POW-LVM3K-24V-H |
Utility/Grid Charging |
|
Battery type |
Lead Acid or Lithium Battery |
Maximum Charging Current (AC) |
40A |
Unstable Condition Error |
± 5Adc |
Charging Voltage Range |
20 – 33Vdc |
Short-circuit protection |
Circuit breaker and blown fuse |
Circuit Breaker Specifications |
40A |
Overcharge Protection |
Yes; Automatically alerts and then turns off charging after1 minute |
Solar (PV) Charging |
|
Recommended PV Max |
100Vdc |
PV Operating Voltage |
30-100Vdc |
MPPT Voltage Range |
30-95Vdc |
Battery Charging Range |
20-33Vdc |
Maximum Input Power |
1400W |
Maximum Input Current |
60A |
Maximum Output Power |
1400W |
PV Charging Current Range |
0-60A |
Short-circuit Protection |
Blown fuse |
Wiring Protection |
Reverse Polarity |
General |
|
Certifications |
FCC Part 15 Class B, RoHS |
Operating Temperature |
5°F ~ 131°F/ -15°C ~ 55°C |
Storage Temperature |
-13°F ~ 140°F / -25°C ~ 60°C |
Humidity |
5% to 95% (three-layer paint protection) |
Noise |
≤60dB |
Cooling |
Fans |
IP Grade |
IP 20 |
Safety Class |
I |
Dimensions (L-W-D) |
14.8*11*4.05 in / 378mm*280mm*103mm |
Weight |
14.96 lbs /6.8kg |
Non-Lithium Battery Parameters
Battery type Parameters |
Sealed lead acid battery (SLD) |
Colloidal lead acid battery (GEL) |
Vented lead acid battery (FLD) |
User-defined (User) |
Overvoltage |
30.0V |
30.0V |
30.0V |
18~30V |
Equalizing charge voltage |
29.2V |
- |
29.6V |
18~30V |
Boost charge voltage |
28.8V |
28.4V |
29.2V |
18~30V |
Floating charge voltage |
27.6V |
27.6V |
27.6V |
18~30V |
Undervoltage alarm voltage |
22.0V |
22.0V |
22.0V |
18~30V |
Low voltage disconnection |
21.0V |
21.0V |
21.0V |
18~30V |
Discharge limit voltage |
20.0V |
20.0V |
20.0V |
18~30V |
Over-discharge delay time |
5S |
5S |
5S |
1~30S |
Equalizing charge duration |
120 minutes |
- |
120 minutes |
0~600 minutes |
Equalizing charge interval |
30 days |
- |
30 days |
0~250 days |
Boost charge duration |
120 minutes |
120 minutes |
120 minutes |
10~600 minutes |
When modifying parameters in User Mode, the following rules must be followed to set parameters successfully.
- Overvoltage Disconnect > Overvoltage Disconnect Recover ≥ Equalization voltage
≥ Boost voltage ≥ Float voltage - Overvoltage Disconnect > Over Voltage Disconnect Recover
- Low Voltage Disconnect Recover > Low Voltage Disconnect (at least 2V Smaller)< Discharge Limit Voltage
- Undervoltage Recover > Undervoltage Alarm
Please download the product manual as below: