Temank Indoor 40A Solar Charge Controller Features

  • Brand: Temank
  • Application: Indoor
  • 40A MPPT solar charge controller
  • MPPT technology
  • Built-in DSP controller with high performance
  • Automatic battery voltage detection for 12V/24V/36V/48V
  • 3-stage charging optimizes battery performance
  • Overcharge protection, Input PV polarity reverse protection, Output limited current
  • protection, Over-temperature protection
  • Suitable for battery types such as sealed lead acid, vented gel and lithium battery, etc
  • Easy to be mounted

Warning and Caution

Be aware that only qualified professionals could install these controllers. Please read all manuals before installing them.

1) Keep controller away from water. Don’t use wet towel to wipe controller;
2) Keep controller in an environmental temperature from -22℃~+55℃. Avoid direct sunlight;
3) Keep good heat dissipation;
4) Use the pure copper wires and connect all polarity correctly;
5) The load output is only for DC load less 5A current;
6) Please don’t set any parameters if you are not professional since the controller can work fine in default condition except lithium battery.

 

PV Module Requirement

Models: HHJ-30A, HHJ-40A, HHJ-50A, HHJ-60A

HHJ-30A

HHJ-40A

HHJ-50A

HHJ-60A

Maximum PV Array Power

For 12V Battery

400W

480W

600W

720W

For 24V Battery

720W

960W

1200W

1440W

For 36V Battery

1000W

1400W

1800W

2100W

For 48V Battery

1200W

1700W

2200W

2800W

PV Array Open Circuit Voltage (Voc)

@Operating Voltage

For 12V Battery

DC20V~DC80V

For 24V Battery

DC37V~DC105V

For 36V Battery

DC50V~DC160V

For 48V Battery

DC72V~DC160V

Notes: Voc is 1.5 or 2 times than battery voltage, then it’s best efficiency. Please choose the PV modules with right Voc.

 

Air Circuit Breaker and Wires Requirement

Models

HHJ-30A

HHJ-40A

HHJ-50A

HHJ-60A

Copper wires

6mm²

6mm²

6mm²x2PCS

6mm²x2PCS

Air circuit breakers

63A

63A

63A

100A

Reminder

For S3-30A and S3-40A, you can connect one wire to one PV+ and another wire to one PV-

For S3-50A and S3-60A, it’s better to connect two wires to two PV+ and another two wires to two PV-

For BAT+ and BAT-, it’s same way to connect wires

Installation steps

  1. The battery voltage should be more than 12V, then the controller can boot up. Install air circuit breaker between controller and batteries. Turn off the circuit breaker, then connect batteries to controller with correct polarity;
  2. Install air circuit breaker between controller and PV modules. Turn off the circuit breaker, and ensure the PV polarity correct, then connect wires between PV modules and controller;
  3. Turn on the air circuit breaker between controller and batteries;
  4. Turn on the air circuit breaker between controller and PV modules;
  5. The controller goes into the self-test mode. Its LCD displays the parameters if all is correct. And RUN lamp (under the fan inside of casing) will flash every one second. If the controller is no response, please read full manual again for reinstalling or contact us for help

MPPT Solar Charger Controller

LCD Display

Item

Description

1

PV voltage / Output power

2

Battery voltage / Charging current

3

Working mode / Temperature

4

Protection mode

Working mode

3.0

Night mode, no charging

4.0

MPPT mode

7.0

Absorption mode

8.0

Floating mode

Troubleshooting

Code

Description

How to solve

18

Input PV voltage is low

Increase the PV voltage

60

Over-temperature protection

Fan will work and temperature reduction automatically

63

Battery voltage is high

Battery high voltage protection and wait for recovery

65

Battery voltage is low

Battery over-discharge and wait for recovery

71

Input PV voltage is high

Decrease the PV voltage

73

Over-charging current

Decrease the PV power

Basic Parameter

Models

S3-30A

S3-40A

S3-50A

S3-60A

Charging mode

3-stage: constant current(MPPT), constant voltage, floating

Battery voltage automatic recognition: 12V Battery

DC9V~DC15V

Battery voltage automatic recognition: 24V Battery

DC18V~DC29V

Battery voltage automatic recognition: 36V Battery

DC30V~DC39V

Battery voltage automatic recognition: 48V Battery

DC40V~DC60V

Overcharging protection voltage

15V

30V

45V

60V

Limited current protection

31A

42A

51A

61A

Max efficiency

≥98.1%

PV utilization

≥99%

Protection function

Temperature protection

75℃

Fan-on temperature

>45℃

Fan-off temperature

<40℃

Properties

Size (mm)

214x115x50

Net weight(Kg)

1.1

Gross weight(Kg)

1.2

Electromagnetic compatibility

Accord to EN61000, EN55022, EN55024

Enclosure

IP21

Environmental temperature

-20℃ ~ +55℃

Storage temperature

-40℃ ~ +75℃ 

Manual Setting

Reminder: The controller will work fine under default setting except lithium battery.

Caution! All steps must be carried out when the PV modules are disconnected to controller.

Step 1: D00

Press the button PRG, then LCD displays D00. This is setting for load working time (Default is 24-hour). Press ENT until numbers flash, then press UP/DOWN to set up time that you want, long-press ENT to confirm it. This output voltage is same as battery. The load is only for small DC loads less 5A current. If no load, just leave it.

Step 2: D01

Press the button UP, LCD shows 13.8. This is default value of floating charging. Press ENT until numbers flash, then press UP/DOWN to set up voltage that you want, long-press ENT to confirm it.

Caution! This value is for one 12V battery. If there are many batteries in series, the controller will multiply them in proportion automatically and the LCD only displays the voltage of one battery (For example, if your battery is 4x12V, and if you set the voltage at 14.1, the charge voltage will be 4x14.1 automatically, but the LCD only displays 14.1).

Step 3: D02

Continue to press the button UP, LCD shows 14.5. This is highest absorption charging voltage for battery. Press ENT until numbers flash, then press UP/DOWN to set up voltage that you want, long-press ENT to confirm it.

Caution! This value is for one 12V battery. If there are many batteries in series, the controller will multiply them in proportion automatically and the LCD only displays the voltage of one battery.

Step 4: D03

Continue to press the button UP, LCD shows 10.0. This is protection value of battery discharge. Press ENT until numbers flash, then press UP/DOWN to set up voltage that you want, long-press ENT to confirm it. It means it’s protected when 12V battery is less 10.0V and there is no output power from OU+ and OU-.

Step 5: D04

Continue to press the button UP, LCD shows 00. 00 is default for acid batteries.

If it’s for lithium battery, please press ENT until numbers flash, then press UP/DOWN to choose 01, long-press ENT to confirm it. Step 2 (D01) is no useful when you choose 01 for lithium battery. And the voltage set in step 3 (D02) will be highest charging voltage for lithium battery. Press ESC to exit the setting menu.
Reminder: When you set up all steps, please disconnect battery. And reconnect controller to see if all setting is successful. When all setting is ok, then connect PV modules to controller.

Batteries charge voltage reference

Battery Type

Absorption Voltage ( Constant voltage )

Floating Voltage

 

12V

24V

48V

12V

24V

48V

Vented

14.2V

28.6V

57.2V

13.2V

26.4V

52.80V

Sealed

14.4V

28.8V

57.6V

13.8V

27.6V

55.2V

Gel

14.4 V

28.8V

57.6V

13.8V

27.6V

55.2V

NiCd

14.2V

28.6V

57.2V

14.0V

28.0V

56.0V

Lithium or others

Defined by users

Temank 40A MPPT Solar Charge Controlle Dimension

60A MPPT Solar Charge Controller

Notes: Please use our screws only since it may damage the internal PCB if using other screws. Please use proper torque to push the screws into casing since it may damage the internal PCB by strong torque.

Temank Solar Charge Controller Package Include:

  • Indoor Solar Charge Controller * 1
  • English manual * 1
  • Corner connections * 4
  • Screws for controller casing * 4

Temank Indoor 40A Solar Charge controller Manual down