Temank Solar Charge Controller Parameters

Model

EM2420

EM2430

EM2440

EM2450

EM2460

Product

Category

MPPT effldency

≥ 99.5%

Standby consumption

0.5~1.2W

Heat-dissipating Method

Natural-Cooling

 

12V system

9VDC-15VDC(Lead acid)

Battery System Voltage Range

24V system

18VDC-30VDC(Lead acid)

Li-lon

8VDC-30VDC(Default), ≤30VDC(Optional Activation Function)

Input Characteristics

Max. PV input voltage(Voc)

100VDC(Default), DC150V(Optional for SMXXX)

Min. Vmpp Voltage

Battery voltage + 2V

Start-up Charging Voltage

Battery voltage + 3V

Low iput Voltage protection

Battery voltage +2V

Over Voltage Protection/Recovery

100VDC/95VDC(Default), 150VDC/145VDC(Optional)

Related PV Power

12V System

260W

390W

520W

esow

7BGW

24V system

520W

780W

1040W

1300W

1560W

Li-lon

252W-504W

37BW-766W

5O4W-10G8W

630W-1260W

766W-1512W

Ch«rg.

Charactorisdca

Activation For Lithium Battery

Optional

Battery Types(Default Gel Battery)

Sealed(SEL), Gel(GEL), Flooded(FLD), User-defined(USE), Li-ion(Lit)

Reted Charge Current

20A | 30A | 40A | 50A | 60A

Temperature Compensation

-3mV/℃/2V(default)

Charge method

3-stages: CC(Constant Current), CV(Constant Voltage), CF(Floating Charge)

Output Voltage Stability Accuracy

≤±0.2V

LOAD ChanctMtattcs

Load Vlotage

Same As Battery Voltage

Rated Load Current

20A | 30A

Load control mode

On/Off Mode, PV Voltage Control Mode, Dual-time Control Mode, PV+Time Control Mode

Low Voltage Protection

10.5V(Default), 11V(Restored), Settable

Setting method

PC Software/APP/Controller

Dfopfay.

Conwnunicatkm

Display

High-Definition LCD Segment Code Backlight Display

Communication

Dual RJ45 Port/RS485 Protocol/PC(Via RS485-USB Cable)&APP(via Wi-Fi Module)/Centralized Monitoring(Via Parallel Connection and RS485-USB Cable)

Other

Parameters

Protection

Input & Output Over-Volt/Low-Voltage Protection, Reverse Polarity Protection, Over-Heating Protection, Battery Shedding Protection etc.

Operating Ambient Temperature

-20℃~+50℃

Storage Temperature

-40℃~+75℃

IP(Ingress Protection)

IP43

Noise

≤10dB

Altitude

0-3000m
Max.Wiring Size

28mm2

Recommended Breaker

≥40A| ≥63A

≥63A | ≥100A | ≥100A

N.Weight(kg)/G.Weight

1.65/1.98

2.35/2.78

Product Size/Packing Size(mm)

220*148x58.5/289x212x105

245x170x63.5/334x225x123

 

LCD Displayarea Description

 

Temank Solar Charge Controller EM2440 40A 12V 24V

Button Operation:(Four Buttons: PV, BAT/UP, DC/down, S)

Temank, Solar Charge Controller, MPPT

Common Fault And Trouble Shooting