Temank Intelligent PWM 80A 12V 24V 36V 48V Solar Panel Charge Controller With LCD Display
Temank Intelligent PWM 80A 12V 24V 36V 48V Solar Panel Charge Controller With LCD Display
Temank Intelligent PWM 80A 12V 24V 36V 48V Solar Panel Charge Controller With LCD Display
Temank Intelligent PWM 80A 12V 24V 36V 48V Solar Panel Charge Controller With LCD Display

Temank Intelligent PWM 80A 12V 24V 36V 48V Solar Panel Charge Controller With LCD Display

Regular price
$65.99$65.99
Sale price
$65.99$65.99
Unit price
per 

BSC8048 Series Solar Charge Controller  Features:

This BSC8048 series controller is a PWM charge controller with built in LCD that adopts the most advanced digital technique. The multiple load control modes enable it can be widely used on solar off grid system, traffic signal, solar street light, etc.

  • Brand: Temank
  • Product No.: BSC8048
  • System voltage of battery 12V/24V/36V/48V automatic recognition;
  • Intelligent 4 stages PWM charging: Bulk, Absorption, Equalize, Float;
  • LCD display with Back-lighting shows device’s operating data and working condition;
  • Humanized simple button operation; Adjustable charge-discharge control parameters;
  • Support more kinds of battery: Lead-acid battery (Sealed, Gel, Flooded) and Lithium battery (LiCoMnNiO2, LiFePO4);
  • Multiple load control modes: 24Hours Working Control, Light Control, Light and Dual Time Control;
  • Automatic temperature compensation and accumulated function of charge and discharge KWH;
  • Double USB output 5V/2A;
  • Perfect electronic protections

Solar Charge Controller BSC8048 Series Specification:

Max Current

10A/20A

30A/40A

50A/60A

80A

Battery Voltage

12V/24V Auto

12V/24V/36V/48V Auto

Max PV Open Circuit Voltage

100V

Self-consumption

≤30mA

Loop Voltage Drop

≤0.3V

USB Output

5V/2A *2

Temperature Compensation

-4mV/℃/2V (25℃)

Operating Temperature

-20℃~+50℃

Protection Category

IP32

Humidity

95%, no-condensing

Terminals

8AWG/10mm²

6AWG/16mm²

4AWG/25mm²

Mounting Hole Size

137*52mm-Φ6mm

177*60mm-Φ5mm

190*104mm-Φ5mm

Dimension

147*82*36mm

187*96*47mm

200*132*61mm

200*132*62mm

Weight

0.22KG

0.19KG

0.4KG

0.73KG

0.79KG

System Connection:

 Temank Intelligent PWM 20A 12V 24V Solar Panel Charge Controller, Solar Charge Controller

Order of Connection:

① Connected with Battery first; ② Connected with Load; ③ Connected with Solar Panel.

Note:

① This series is a positive ground controller. Any positive connection of Solar Panel, Load or Battery can be earth grounded;
② The fuse should be installed as close to battery as possible, the suggested distance is about 150mm;
③ If inverter or other load with big start current is necessary in system, please connect it with Battery, not solar controller;
④ When disconnecting the system, the order will be reversed.

Operation:

LCD Symbol:

 Temank Intelligent PWM 20A 12V 24V Solar Panel Charge Controller

Button Function:

Solar Charge Controller, Temank Intelligent PWM 20A 12V 24V Solar Panel Charge Controller

Browse Interface:

Solar Panel Charge Controller, Temank, PWM Techonlogy

NOTE:

① After connected with Battery, LCD will go into an interface that automatically recognizes the battery voltage level, 3 seconds later, it will enter to the main interface of LCD;
② Equalizing charge will be after every 90 times Floating charge, or one charge in three months;
③ Default maximum charging current of Lithium battery is 5A, but it can be adjusted by users within the rated current range.
④ Under the interface of Accumulated KWH, long press button “+” to clear the value; ⑤When no operation 30s, the interface will be back to main interface, and back-light will be turned off.

Battery Types:

Under the interface of battery types, long press button “” into the type setting, then short press button “” or “” to choose battery type, and then long press “” again to save and exit.

Icon

Battery Type

SLD

Sealed Battery (Default)

GEL

Gel Battery

FLD

Flooded Battery

USE1

Lead-Acid Battery (User-defined)

3.2-4

LiFePO4: 3.2V-4S /8S /12S /16S

3.2-5

LiFePO4: 3.2V-5S /10S /15S /20S

3.7-3

LiCoMnNiO2: 3.7V-3S /6S /9S /12S

3.7-4

LiCoMnNiO2: 3.7V-4S /8S /12S /16S

USE2

Lithium Battery (User-defined)

 

Battery voltage automatic identification range:

Battery Types

Lead-Acid Battery

Lithium Battery

LiFePO4

3.2V-4

LiFePO4

3.2V-5

LiCoMnNiO2

3.7V-3

LiCoMnNiO2

3.7V-4

12V System

≤17.6V

≤18V

≤22.5V

≤15.9V

≤21.2V

24V System

≤29.9V

≤30.4V

≤38V

≤26.9V

≤35.8V

36V System

≤42.1V

≤42.8V

≤53.5V

≤37.8V

≤50.4V

48V System

>42.1V

>42.8V

>53.5V

>37.8V

>50.4V

 

Control Parameters Of Lead-acid Battery:

Lead-Acid Battery Types

SLD

GEL

FLD

Battery Voltage Level

12V

24V

36V

48V

12V

24V

36V

48V

12V

24V

36V

48V

Float

Charging Voltage

13.8V

27.6V

41.4V

55.2V

13.8V

27.6V

41.4V

55.2V

13.8V

27.6V

41.4V

55.2V

Absorption

Charging Voltage

14.4V

28.8V

43.2V

57.6V

14.2V

28.4V

42.6V

56.8V

14.6V

29.2V

43.8V

58.4V

Equalizing

Charging Voltage

14.6V

29.2V

43.8V

58.4V

NO

14.8V

29.6V

44.4V

59.2V

Charging time of

Absorption/Equalizing

2 Hours

 

Lead-Acid Battery Types

SLD / GEL / FLD

Battery Voltage Level

12V

24V

36V

48V

Low Voltage Disconnection

10.7V

21.4V

32.1V

42.8V

Low Voltage Re-connection

12.6V

25.2V

37.8V

50.4V

Load Over-Voltage Disconnection

16V

32V

48V

64V

Load Over-Voltage Re-connection

15.5V

31V

46.5V

62V


C
ontrol parameters of Lithium battery:

Lithium Battery Type

LiFePO4

Icon

3.2-4

3.2-5

Battery Serial Number

4S

8S

12S

16S

5S

10S

15S

20S

Recovery

Charging Voltage

13.6V

27.2V

40.8V

54.4V

17V

34V

51V

68V

Constant

Charging Voltage

14.4V

28.8V

43.2V

57.6V

18V

36V

54V

72V

Stop Charging Current

0.1A

0.1A

Low Voltage

Disconnection

11.2V

22.4V

33.6V

44.8V

14V

28V

42V

56V

Low Voltage

Re-connection

12.8V

25.6V

38.4V

51.2V

16V

32V

48V

64V

Load Over-Voltage Disconnection

18.5V

37V

55.5V

74V

18.5V

37V

55.5V

74V

Load Over-Voltage Re-connection

18V

36V

54V

72V

18V

36V

54V

72V

 

Lithium Battery Type

LiCoMnNiO2

Icon

3.7-3

3.7-4

Battery Serial Number

3S

6S

9S

12S

4S

8S

12S

16S

Recovery

Charging Voltage

12V

24V

36V

48V

16V

32V

48V

64V

Constant

Charging Voltage

12.6V

25.2V

37.8V

50.4V

16.8V

33.6V

50.4V

67.2V

Stop Charging Current

0.1A

0.1A

Low Voltage

Disconnection

9.9V

19.8V

29.7V

39.6V

13.2V

26.4V

39.6V

52.8V

Low Voltage

Re-connection

11.1V

22.2V

33.3V

44.4V

14.8V

29.6V

44.4V

59.2V

Load Over-Voltage

Disconnection

18.5V

37V

55.5V

74V

18.5V

37V

55.5V

74V

Load Over-Voltage

Re-connection

18V

36V

54V

72V

18V

36V

54V

72V

 Load Working Modes:

Under the load mode setting interface, long press button “+”, when Timer 1 or Timer 2 begin flashing, short press button “+” or “-” to set parameter, then long press button “+” to save and exit.

 Solar Charge Controller, Temank, PWM technology

Icon

Load Working Mode Timer 1

Icon

Load Working Mode Timer 2

24h

Load 24 Hours working (Default).

200

Disable.

00h

Light Control: Load On since sunset, Load Off when sunrise.

200

Disable.

101~115

Load On for 1~15 hours since sunset.

200~215

Load On for 1~15 hours before sunrise.

-00h

Reversed Light Control: Load On since sunrise, Load Off when sunset.

200

Disable.

Protections:

  • Solar Panel Reverse-Polarity: If the solar panel is connected with controller in reversed polarity, controller will not be damaged and will work as normal when correctly connected.
  • Battery Reverse-Polarity: If the battery is connected with controller in reversed polarity (solar controller is not connected with solar panel), controller will not be damaged and will work as normal when correctly connected.
  • Battery Reverse-Discharge: Controller is able to protect battery from reversed discharging to solar panel at night.
  • Over-Heating Protection: Once the internal temperature is detected to be higher than a certain value by the controller, it will stop charging the battery and then recharging the battery automatically after the temperature drop to a certain value.
  • Battery Over-Current: Controller will stop charging when excess current is detected from the solar panel, and recharging automatically after 2 min.
  • Load Over-Load: The load will be turned off when the output current of load exceeds its rated current for a while, and turned on automatically after 2 min.
  • Load Short-Circuit: Controller will be in protection state when the load is short circuit, and recharging automatically after 2 min.
  • Battery Low-Voltage: Controller will turn off the load when the battery voltage is lower than the value preset for low-voltage disconnection, and turn on the load when the battery voltage reaches the value preset for low-voltage re-connection. The value for low-voltage disconnection and low-voltage re-connection can be set by users in a certain range.
  • Battery Over-Voltage: Controller will turn off the load when the battery voltage is higher than the value preset for over-voltage protection, and turn on the load when the battery voltage is 1V lower than the value preset for over-voltage protection.
  • Lightning Protection: The lightning protection function of controller is limited and it is recommended to install devices for lightning protection on the input side to increase system reliability.

Troubleshooting:

Error Code

Cause

Solution

E01

Battery Low-Voltage

Recharging the battery or change a new one.

E02

Load Over-Load

Check the loads connection or reduce the electric equipment.

E03

Load Short-Circuit

E04

Load Over-Voltage

E05

Solar Panel Over-Current

Check the power of solar panel or reduce the solar panel.

There is detail information for you to reference as below:
TEMANK BSC8048 INTELLIGENT SOLAR CHARGE CONTROLLE USER’S MANUAL