- Brand: Temank
- Product Model:S60
- Technology: PWM
- LCD screen display
- Battery reverse discharge protection
- Easy operation interface
- Battery reverse polarity protection
- PWM charging mode
- Battery under voltage protection
- Parameter user can reset
- Overload, short-circuit protection
- A key to open and close the load
- Automatic temperature compensation function
- A key to restore the factory settings
- Optional USB 5V charging (for 500mA)
Temank PWM 60A 12V 24V Solar Charge Controller Specification
model Parameters |
Solar30/60/80 |
model Parameters |
Solar30 |
Solar60 |
Solar80 |
||
Rated working current |
30A |
60A |
80A |
Cable |
≤7# AWG (10mm2) |
(20mm2) |
(25mm2) |
Rated working voltage |
12V/24V |
Working temperature |
-10℃~60℃ |
||||
Solar panels voltage |
≤48V |
Storage temperature |
-30℃~70℃ |
||||
Float charging voltage(settable) |
13.8V/27.6V |
Humidity requirements |
≤90%, |
||||
Low voltage protection(settable) |
10.7V/21.4V |
dimension |
90 mm×188 mm×50mm |
128 mm×188 mm×61mm |
128 mm×188 mm×61mm |
||
Low voltage recovery(settable) |
12.5V/25.0V |
Mounting hole spacing |
60 mm×178 mm --Φ5 |
98mm×178 mm --Φ5 |
98 mm×178 mm --Φ5 |
||
No-load loss |
≤25mA |
weight |
≤360g |
≤800g |
≤1000g |
||
Loop pressure drop |
≤160mV |
Temperature compensation |
-4mV/Cell/℃ |
||||
Charging mode |
PWM mode |
Temank PWM 60A 12V 24V Solar Charge Controller Solar60 For PV System Instructions
- Ready Qi installation tools and materials, and cable. Please matching suitable cable
- Ensure that the current density <4A/mm2 this will help to reduce the line pressure drop.
Recommended: 30A current 10mm2 60A current 20mm2 80A current 25 mm2 cable. Check whether the installation site
Comply with the relevant safety requirements, avoid damp, dusty, there is easyInflammable, explosive and corrosive gases place to install using the controller - Install the controller fixed to the vertical plane, see Section V mounting aperture and hole spacing. In order to ensure a good controller cooling conditions, the controller on the bottom of each reserved 10cm space
- As shown on the right wiring sequence: load, battery, solarQ Battery plate is connected to the controller to be taken to ensure that the load, battery, The polarity of the solar cell panel and controller
- Before use: external temperature sensor probe into the left of the controller temperature probe interface probe placed in similar battery temperature. (Line extension must be built-in devices of the external temperature probe coextensive Otherwise, the controller will control parameters of the temperature compensation of the error
- Warning: In order to prevent accidents from occurring, install: non-professionals can not be engaged in loading and unloading operations
LCD operating interface description
Function keys
Parameter settings (≥ 5 seconds keystrokes, parameters are savedautomatically)
3Parameter settings (≥ 5 seconds keystrokes, parameters are saved automatically)
4Common fault with processing methods
- Under voltage protection and handling: screen display as shown on the right indicates the battery voltage is below the undervoltage protection voltage, the controller has entered undervoltage
- Retaining state, disconnect the load circuit. Using solar panels or charger to charge the battery when the accumulator
- After the battery voltage reaches the undervoltage recovery voltage, the controller will restore power to the load, into normal working condition
Please download the manual about the Temank PWM 60A 12V 24V Solar Charge Controller Solar60 For PV System as below:
Temank PWM 60A 12V 24V Solar Charge Controller Solar60 For PV System download