  • Brand: Temank
  • Product Model: VS6048AU
  • Technology: PWM
  • Adopt high quality components of ST,IR and Infineon, make sure product using lifespan
  • Terminals have UL and VDE certification, the product is more safer and more reliable
  • Controller can work continuously at full load within the environment temperature range from -25 to 55 ℃
  • 3-Stage intelligent PWM charging:Bulk, Boost/Equalize, Float
  • Support 3 charging options: Sealed, Gel, and Flooded
  • LCD display design, dynamically displaying device’s operating data and working condition
  • Double USB design, the power supply charge for electronic equipment
  • With humanized button settings, operation will be more comfortable and convenient
  • Multiple load control modes
  • Energy statistics function
  • Battery temperature compensation function
  • Battery temperature compensation function
  • Extensive Electronic protection

Temank ViewStar AU 6048 series solar charge controller

Item

VS1024AU

VS2024AU

VS3024AU

VS3048AU

VS4524AU

VS4548AU

VS6024AU

VS6048AU

Nominal system voltage

12/24VDC

Auto

12/24/36/48VDC Auto

12/24VDC

Auto

12/24/36/48VDC Auto

12/24VDC

Auto

12/24/36/48VDC Auto

Battery input voltage range

9V~32V

9V~64V

9V~32V

9V~64V

9V~32V

9V~64V

Rated charge/discharge current

10A@55℃

20A@55℃

30A@55℃

45A@55℃

60A@55℃

Max. PV open circuit voltage

50V

96V

50V

96V

50V

96V

Battery type

Sealed(Default) / Gel / Flooded

Equalize Charging Voltage※

Sealed:14.6V/ Gel: No/ Flooded:14.8V

Boost Charging Voltage※

Sealed:14.4V/ Gel:14.2V/ Flooded:14.6V

Float Charging Voltage※

Sealed/Gel/Flooded:13.8V

Low Voltage Reconnect Voltage※

Sealed/Gel/Flooded:12.6V

Low Voltage Disconnect Voltage※

Sealed/Gel/Flooded:11.1V

Self-consumption

≤9.2mA/12V;≤11.7mA/24V; ≤14.5mA/36V;≤17mA/48V

Temperature compensation coefficient

-3mV/℃/2V(25℃)

Charge circuit voltage drop

≤0.29V

Discharge circuit voltage drop

≤0.16V

LCD temperature range

-20℃~+70℃

Working environment temperature

-25℃~+55℃(Product can work continuously at full load)

Relative humidity

≤95%, N.C. 

Enclosure

IP30

Grounding

Common Positive

USB output

5VDC/2.4A(Total)

Overall dimension

142x85x41.5mm

160x94.9x49.3mm

181x100.9x59.8mm

194x118.4x63.8mm                    

214x128.7x72.2mm                         

Mounting dimension

130x60mm

148x70mm

172x80mm

185x90mm

205x100mm

Mounting hole size

Φ4.5mm

Φ5mm

Φ5mm

Φ5mm

Terminals

4mm2/12AWG

10mm2/8AWG

16mm2/6AWG

16mm2/6AWG

25mm2/4AWG

Net weight

0.22kg

0.35kg

0.55kg

0.58kg

0.76kg

0.88kg

1.02kg

1.04kg

※Above the parameters are in 12V system at 25, twice in 24Vsystem, triple in 36V system and quadruple in 48V system.

 Temank ViewStar AU 1024 series solar charge controller, 10A, 12V, 24V

Figure 1 Characteristic

LCD

Battery Terminals

MENU Button

Load Terminals

RTS Port

SET Button

PV Terminals

USB Output Ports※

Note: USB output ports provide the power supply of 5VDC/2.4A and have the short circuit protection.

 

Temank ViewStar AU 1024 series solar charge controller, temank, 10A, 12V, 24V

Wiring

 

Solar Charge Controller, Temank ViewStar AU 1024 series solar charge controller, Temank

(1) Connect components to the charge controller in the sequence as shown above and pay much attention to the “+” and “-”. Please don’t insert the fuse or turn on the breaker during the installation. When disconnecting the system, the order will be reserved.

(2)After power on the controller, check the LCD on. Otherwise please refer to chapter 6.Always connect the battery first, in order to allow the controller to recognize the system voltage.

(3)The battery fuse should be installed as close to battery as possible. The suggested distance is within 150mm.

(4) The VS AU series is a positive ground controller. Any positive connection of solar, load or battery can be earth grounded as required.

NOTE: Please connect the inverter or other load that it has the large start current to the battery rather than to the controller, if the inverter or other load is necessary.

Protections

Protection

Conditions

Status

PV Reverse Polarity

When the battery is correct connecting, the PV can be reversed.

The controller is not damage

Battery Reverse Polarity

When the PV is not connecting, the battery can be reversed.

Battery Over Voltage

The battery voltage reaches to the OVD

Stop charging

Battery Over Discharge

The battery voltage reaches to the LVD

Stop discharging

Battery Overheating

Temperature sensor is higher than 65℃

Output is OFF

Temperature sensor is less than 55℃

Output is ON

Controller Overheating

Temperature sensor is higher than 85℃

Output is OFF

Temperature sensor is less than 75℃

Output is ON

Load Short Circuit

Load current ≥2.5 times rated current 

One short circuit, the output is OFF 5s;

Two short circuit, the output is OFF 10s;

Three short circuit, the output is OFF 15s;

Four short circuit, the output is OFF 20s;

Five short circuit, the output is OFF 25s;

Six short circuit, the output is OFF

Output is OFF

Clear the fault: Restart the controller or wait for one night-day cycle (night time>3 hours).

Load Overload

Load current ≥2.5 times rated current 

1.02-1.05 times, 50s,

1.05-1.25 times, 30s

1.25-1.35 times,10s

1.35-1.5 times 2s

Output is OFF

Clear the fault: Restart the controller or wait for one night-day cycle (night time>3 hours).

Damaged RTS

The RTS is short-circuited or damaged

Charging or discharging at 25℃

Disclaimer

This warranty does not apply under the following conditions:

  1. Damage from improper use or use in an unsuitable environment.
  2. PV or load current, voltage or power exceeding the rated value of controller.
  3. The controller is working temperature exceed the limit working environment temperature.
  4. User disassembly or attempted repair the controller without permission.
  5. The controller is damaged due to natural elements such as lighting.
  6. The controller is damaged during transportation and shipment.

You can get more information about Temank VS 6048AU series as below:

Temank VS 6048AU series manual